MI 3380-2012
МИ 3380-2012
|
|
State system for ensuring uniformity of measurements. Volume flow transducers. Methods of verification on-site calibration equipment
Государственная система обеспечения единства измерений. Преобразователи объемного расхода. Методика поверки на месте эксплуатации поверочной установкой
Status: Effective
The calibration method applies to volume flow converters operated as part of SIKN, SIKNS, SIKNP and SIKZHU, and establishes the order of their primary and periodic on-site verification using PU. According to the method, turbine and volume-blade transducers having a frequency (pulse) output signal are verified, and under the condition that the calibration characteristic of the transducer is realized (implemented) by one of the methods outlined in this method.
Методика поверки распространяется на преобразователи объемного расхода, эксплуатируемые в составе СИКН, СИКНС, СИКНП и СИКЖУ, и устанавливает порядок их первичной и периодической поверок на месте эксплуатации с помощью ПУ. По методике поверяют турбинные и объемно-лопастные преобразователи, имеющие частотный (импульсный) выходной сигнал, и при условии, если градуировочная характеристика преобразователя реализуется (реализована) по одному из способов, изложенных в настоящей методике.
Choose Language:
Format: Electronic (pdf/doc)
Approved: FSUE VNIIR-GNMTS,
9/10/2012
SKU: RUSS154438
The Product is Contained in the Following Classifiers:
PromExpert »
SECTION II. METROLOGICAL »
I Organizational and technical bases of metrological support »
2 Technical basics of metrological support »
2.3 Verification, calibration and testing of measuring instruments »
2.3.3 Measurement of flow parameters, flow rate, level, volume of substances »
ISO classifier »
17 METROLOGY AND MEASUREMENTS. PHYSICAL PHENOMENA »
17.220 Electricity. Magnetism. Electrical and magnetic measurements »
17.220.99 Electricity and magnetism, other aspects »
As a Replacement Of:
MI 1974-2004: State system for ensuring uniformity of measurements. Turbine flow transducers. Method of verification
The Document References:
GOST 112-41: Mercury meteorological thermometers (Savinov). Specification
GOST 1756-2000: Petroleum products. Determination of saturated vapours pressure
GOST 2477-65: Petroleum and petroleum products. Method for determination of water content
GOST 2517-85: Crude oil and petroleum products. Methods of sampling
GOST 33-2000: Petroleum products. Transparent and opaque liquids. Determination of kinematic viscosity and calculation of dynamic viscosity
GOST 8.207-76: Direct measurements with multiple observations. Observation data processing methods
GOST R 51330.0-99: Explosionproof electrical apparatus. Part 0. General requirements
GOST R 8.654-2009: State system for ensuring the uniformity of measurements. Requirements for software of measuring instruments. Main principles
MI 2083-90: Indirect measurements. Determination of the measurement results and the estimation of their errors
MI 2676-2001: Recommendation. State system for ensuring uniformity of measurements. Methods of metrological certification of algorithms and programs for processing data from measurement results when determining the volume and mass of oil and petroleum products. General
MI 2955-2010: Recommendation. State system for ensuring uniformity of measurements. Typical methods of certification of software measuring devices
MI 3002-2006: Recommendation. State system for ensuring uniformity of measurements. Rules for sealing and marking of measuring instruments and equipment used in the composition of the systems for measuring the amount and indicators of oil quality and calibration facili
PB 03-585-03: Process Pipelines Design and Safe Operation Rules
PB 08-624-03: Safety Regulations for oil and gas industry
POT R M-016-2001: Inter-Industry Occupational Safety and Health Regulations (Safety Regulations) for Operation of Electrical Installations
PR 50.2.006-94: Procedure for calibration of measurement equipment
PR 50.2.007-2001: State system for ensuring the uniformity of measurements. Verification marks
PR 50.2.104-09: State system for ensuring uniformity of measurements. Procedure for testing standard samples or measuring instruments for type approval
PR 50.2.105-09: Procedure for approving the type of reference standards or reference measuring instruments
PR 50.2.106-09: State system for ensuring uniformity of measurements. The procedure for issuing certificates of approval of the type of reference materials or the type of measuring instruments, the establishment and change of the validity of these certificates and the interval between inspections of measuring instruments
PR 50.2.107-09: State system for ensuring uniformity of measurements. Requirements for approval marks of the type of reference materials or the type of measuring instruments and the procedure for their application
R 50.2.075-2010: State System for ensuring the uniformity of measurements. Crude Petroleum and Petroleum Products. Laboratory Methods for Determination of Density, Relative Density and API Gravity
R 50.2.076-2010: State system for ensuring the uniformity of measurements. Density of petroleum and petroleum products. Methods of calculation. Programme and tables of calculation
The Document is Referenced By:
MI 3532-2015: State system for ensuring the uniformity of measurements. Recommendations on definition of weight of oil at registration operations with application quantity measures and indicators of oil quality
|
Customers Who Viewed This Item Also Viewed:
 |
Cylindrical evolvent gears of external engagment. Strength calculation
Language: English |
Plastics structured-wall pipes and their fittings for sewerage systems outside the buildings. Specifications
Language: English |
Vegetable oils. General technical requirements
Language: English |
Current transformers. General specifications
Language: English |
 |
|
YOUR ORDERING MADE EASY!
RussianGost.com is an industry-leading company with stringent quality control standards and our dedication to precision, reliability and accuracy are some of the reasons why some of the world’s largest companies trust us to provide their national regulatory framework and for translations of critical, challenging, and sensitive information.
Our niche specialty is the localization of national regulatory databases involving: technical norms, standards, and regulations; government laws, codes, and resolutions; as well as RF agency codes, requirements, and Instructions.
We maintain a database of over 220,000 normative documents in English and other languages for the following 12 countries: Armenia, Azerbaijan, Belarus, Kazakhstan, Kyrgyzstan, Moldova, Mongolia, Russia, Tajikistan, Turkmenistan, Ukraine, and Uzbekistan.
Placing Your Order
Please select your chosen document, proceed to the ‘checkout page’ and select the form of payment of your choice. We accept all major credit cards and bank wire transfers. We also accept PayPal and Google Checkout for your convenience. Please contact us for any additional arrangements (Contract agreements, PO, etc.).
Once an order is placed it will be verified and processed within a few hours up to a rare maximum of 24 hours.
For items in stock, the document/web link is e-mailed to you so that you can download and save it for your records.
For items out of stock (third party supply) you will be notified as to which items will require additional time to fulfil. We normally supply such items in less than three days.
Once an order is placed you will receive a receipt/invoice that can be filed for reporting and accounting purposes. This receipt can be easily saved and printed for your records.
Your Order Best Quality and Authenticity Guarantee
Your order is provided in electronic format (usually an Adobe Acrobat or MS Word).
We always guarantee the best quality for all of our products. If for any reason whatsoever you are not satisfied, we can conduct a completely FREE revision and edit of products you have purchased. Additionally we provide FREE regulatory updates if, for instance, the document has a newer version at the date of purchase.
We guarantee authenticity. Each document in English is verified against the original and official version. We only use official regulatory sources to make sure you have the most recent version of the document, all from reliable official sources.