imgalt

GOST IEC 62606-2016

ГОСТ IEC 62606-2016

Arc fault detection devices for household and similar use. General requirements

Устройства защиты бытового и аналогичного назначения при дуговом пробое. Общие требования

Status: Effective - Introduced for the first time. IUS 10-2017

This standard applies to protection devices for arc breakdown detection (UZDP) of household and similar purposes used in AC circuits. This standard applies to devices that simultaneously detect and limit the arc current to prevent a fire hazard, and defines operating criteria for opening the circuit under specified conditions if the arc current exceeds the limits specified in this standard

Настоящий стандарт распространяется на защитные устройства обнаружения дугового пробоя (УЗДП) бытового и аналогичного назначения, применяемые в цепях переменного тока. Настоящий стандарт распространяется на устройства, которые одновременно выполняют обнаружение и ограничение тока дуги для предупреждения опасности пожара, и определяет рабочие критерии размыкания цепи в заданных условиях, если ток дуги превышает предельные значения, указанные в настоящем стандарте

Choose Language: 
Format: Electronic (pdf/doc)

Approved: Federal Agency for Technical Regulation and Metrology, 5/23/2017

SKU: RUSS287151

Price: $2,057.00



imgalt

The Product is Contained in the Following Classifiers:

Construction (Max) » Standards » Other state standards used in construction » 29 Electrical Engineering »

ISO classifier » 29 ELECTRICAL ENGINEERING » 29.120 Electrical fittings » 29.120.50 Fuses and other protective devices in case of overload »

National standards » 29 ELECTRICAL ENGINEERING » 29.120 Electrical fittings » 29.120.50 Fuses and other protective devices in case of overload »


The Document References:

GOST 14254-96: Degrees of protection provided by enclosures (IP Code)

GOST 27483-87: Fire hazard testing. Test methods. Glow-wire test and guidance

GOST 28216-89: Basic environmental testing procedures. Part 2. Tests. Test Db and guidance: damp heat, cyclic (12 + 12 hour cycle)

GOST 30331.1-2013: Low-voltage electrical installations. Part 1. Fundamental principles, assessment of general characteristics, definitions

GOST 30331.4-95: Electrical installations of buildings. Part 4. Protection for safety. Protection against thermal effects

GOST 30331.5-95: Electrical installations of buildings. Part 4. Protection for safety. Protection against overcurrent

GOST 30331.6-95: Electrical installations of buildings. Part 4. Protection for safety. Protection against undervoltage

GOST 30331.7-95: Electrical installations of buildings. Part 4. Protection for safety. Insulation, switching off, control

GOST 30331.9-95: Electrical installations of buildings. Part 4. Protection for safety. Measures of protection against overcurrent

GOST 31216-2003: Еlectromagnetic compatibility of technical equipment. Residual current-operated protective devices (rcds) for household and similar use. Requirements and test methods

GOST CISPR 14-1-2015: Electromagnetic compatibility. Requirements for household appliances, electric tools and similar apparatus. Part 1. Emission

GOST IEC 61008-1-2012: Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB'S). Part 1. General rules

GOST IEC 61009-1-2014: Switches, automatic, triggered by residual current, with built-in protection against overcurrent, household and similar purposes. Part 1. General rules

GOST R 50571.10-96: Electrical installations of buildings. Part 5. Selection and erection of electrical equipment. Chapter 54. Earthing arrangements and protective conductors

GOST R 50571.11-96: Electrical installations of buildings. Part 7. Requirements for special installations or locations. Section 701. Locations containing a bath tub or shower basin

GOST R 50571.12-96: Electrical installations of buildings. Part 7. Requirements for special installations or locations. Section 703. Locations containing sauna heaters

GOST R 50571.13-96: Electrical installations of buidings. Part 7. Requirements for special installations or locations. Section 706. Restrictive conducting locations

GOST R 50571.14-96: Electrical installations of buildings. Part 7. Requirements for special installations or locations. Section 705. Electrical installations of agricultural and stock-breeding buildings

GOST R 50571.15-97: Electrical installations of buildings

GOST R 50571.16-99: Electrical installations of buildings. Part 6. Verification. Chapter 61. Initial verification

GOST R 50571.17-2000: Electrical installations of buildings. Part 4. Protection for safety. Chapter 48. Choice of protective measures as a function of external influences. Section 482. Protection against fire

GOST R 50571.18-2000: Electrical installations of buildings. Part 4. Protection for safety. Chapter 44. Protection against overvoltages. Section 442. Protection of low-voltage installations against faults between high-voltage systems and earth

GOST R 50571.19-2000: Electrical installations of buildings. Part 4. Protection for safety. Chapter 44. Protection against overvoltages. Section 443. Protection against overvoltages of atmospheric origin or due to switching

GOST R 50571.1-93: Electrical installations of buildings. General

GOST R 50571.20-2000: Electrical installations of buildings. Part 4. Protection for safety. Chapter 44. Protection against overvoltages. Section 444. Protection against electromagnetic interferences (EMI) in installations of buildings

GOST R 50571.21-2000: Electrical installations of buildings. Part 5. Selection and erection of electrical equipment. Section 548. Earthing arrangements and equipotential bolding for information technology installations

GOST R 50571.22-2000: Electrical installations of buildings. Part 7. Requirements for special installations or locations. Section 707. Earthling requirements for the installation of data processing equipment

GOST R 50571.23-2000: Electrical installations of buildings. Part 7. Requirements for special installations or locations. Section 704. Construction and demolition site installations

GOST R 50571.24-2000: Electrical installations of buildings. Part 5. Selection and erection of electrical equipment. Chapter 51. Common rules

GOST R 50571.25-2001: Electrical installations of buildings. Part 7. Requirements for special installations. Electrical installations of buildings and structures with electrical heating of floors and surfaces

GOST R 50571.26-2002: Electrical installations of buildings. Part 5. Selection and erection of electrical equipment. Section 534. Devices for protection against surge overvoltages

GOST R 50571.27-2003: Electrical installations of buildings. Part 7-740. Requirements for special installations or locations. Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses

GOST R 50571.28-2006: Electrical installations of buildings. Part 7-710. Requirements for special electrical installations. Medical locations

GOST R 50571.2-94: Electrical installations of buildings. Part 3. General characteristics

GOST R 50571.3-94: Electrical installations of buildings. Part 4. Protection for safety. Protection against elecric shock

GOST R 50571.4-94: Electrical installations of buildings. Part 4. Protection for safety. Protection against thermal effects

GOST R 50571.5-94: Electrical installations of buildings. Part 4. Protection for safety. Protection against overcurrent

GOST R 50571.6-94: Electrical installations of buildings. Part 4. Protection for safety. Protection against undervoltage

GOST R 50571.7-94: Electrical installations of buildings. Part 4. Protection for safety. Isolation, switching off, control

GOST R 50571.8-94: Electrical installations of buildings. Part 4. Protection for safety. Application of protective measures for safety. Measures of protection against electric shock

GOST R 50571.9-94: Electrical installations of buildings. Part 4. Security requirements. Application of overcurrent protection measures

Technical regulations of the Customs Union TR TS 004/2011: About the safety of low voltage equipment

The Document is Referenced By:

GOST R 50571.4.42-2017: Low-voltage electrical installations. Part 4-42. Protection for safety. Protection against thermal effects

SP 451.1325800.2019: Public buildings with the use of wooden structures. Design rules

SP 452.1325800.2019: Residential multi-apartment buildings with the use of wooden structures. Design rules

Customers Who Viewed This Item Also Viewed:

imgalt imgalt
Industrial process measurement and control equipment. Reliability. General requirements and test methods
Language: English
Price: $201.00
imgalt
Metals. Methods of tension test
Language: English
Price: $469.00
imgalt
Gauged corrosion-resistant, heat-resistant and high-temperature steel shape
Language: English
Price: $398.00
imgalt
Heating, ventilation and air conditioning. Fire Safety Requirements
Language: English
Price: $295.00
imgalt
Reliability of atomic power stations and their equipment. General statements and reliability index nomenclature
Language: English
Price: $299.00
imgalt
Electromagnetic compatibility of technical equipment. Technical equipment for nuclear power plants. Requirement and test methods
Language: English
Price: $282.00
imgalt
Billets made of corrosion-resistant steels of 12Х18Н9Т, 12Х18Н10Т, 08Х18Н10Т, 10Х17Н13М2Т, 12Х18Н12Т and 03Х21Н32М3Б types.
Language: English
Price: $96.00
imgalt
Dependability in technics. Terms and definitions
Language: English
Price: $233.00
imgalt
System of products development and launching into manufacture. Technical assignment. Requirements to contents and form of presentation
Language: English
Price: $542.00
imgalt
Reliability in technology. Composition and general rules for setting reliability requirements
Language: English
Price: $205.00
imgalt
Stainless corrosion resisting, heat-resisting and creep resisting steel and alloy on iron-nickel-based products. Specifications
Language: English
Price: $282.00
imgalt
Natural gas for industrial and municipal purposes. Technical conditions
Language: English
Price: $267.00
imgalt
Global navigation satellite system. Emergency response system in case of accidents. Test methods for emergency services call device/system for compliance with the requirements for the quality of loudspeaker communication in the vehicle cab.
Language: English
Price: $1,126.00
imgalt

YOUR ORDERING MADE EASY!

RussianGost.com is an industry-leading company with stringent quality control standards and our dedication to precision, reliability and accuracy are some of the reasons why some of the world’s largest companies trust us to provide their national regulatory framework and for translations of critical, challenging, and sensitive information.

Our niche specialty is the localization of national regulatory databases involving: technical norms, standards, and regulations; government laws, codes, and resolutions; as well as RF agency codes, requirements, and Instructions.

We maintain a database of over 220,000 normative documents in English and other languages for the following 12 countries: Armenia, Azerbaijan, Belarus, Kazakhstan, Kyrgyzstan, Moldova, Mongolia, Russia, Tajikistan, Turkmenistan, Ukraine, and Uzbekistan.

Placing Your Order

Please select your chosen document, proceed to the ‘checkout page’ and select the form of payment of your choice. We accept all major credit cards and bank wire transfers. We also accept PayPal and Google Checkout for your convenience. Please contact us for any additional arrangements (Contract agreements, PO, etc.).

Once an order is placed it will be verified and processed within a few hours up to a rare maximum of 24 hours.

For items in stock, the document/web link is e-mailed to you so that you can download and save it for your records.

For items out of stock (third party supply) you will be notified as to which items will require additional time to fulfil. We normally supply such items in less than three days.

Once an order is placed you will receive a receipt/invoice that can be filed for reporting and accounting purposes. This receipt can be easily saved and printed for your records.

Your Order Best Quality and Authenticity Guarantee

Your order is provided in electronic format (usually an Adobe Acrobat or MS Word).

We always guarantee the best quality for all of our products. If for any reason whatsoever you are not satisfied, we can conduct a completely FREE revision and edit of products you have purchased. Additionally we provide FREE regulatory updates if, for instance, the document has a newer version at the date of purchase.

We guarantee authenticity. Each document in English is verified against the original and official version. We only use official regulatory sources to make sure you have the most recent version of the document, all from reliable official sources.

All Codes and Regulations

All Categories

Send us a message Expand Collapse

Leave your message in the form below, and we will write back by e-mail!